Active ProjectNo project selected
New / Open

Engineering / EN 14917 Annex K.12

Gusset with Reinforcing Rings

Ring, pipe, gusset and weld verification according to K.12.1–K.12.4.

1

Load Definition

Vacuum pressure is optional; signed value or magnitude accepted. Pressure is also used for ring/pipe stress in manual F1 mode.

Results

No design-force result yet.

2

Materials

Results

No material result yet.

3

Gusset and Reinforcing Ring Geometry

EN 14917 Figure K.12-1 gusset with reinforcing rings geometry
Figure K.12-1

Geometry preview — based on current inputs

c is the effective pipe length used in the resistant section. It is calculated, not entered: c = 0.78 × √(r × s), where r = (Dp − s) / 2.

Enter positive Dp and s with Dp > s to calculate c and the minimum LG.

Results

No geometry or structural result yet.

4

Gusset, Ring and Pipe Welds

Weld locations a7, a8 and a9 are identified in Figure K.12-1 in the geometry section.

Results

No weld-verification result yet.